Stainless steel for chemical plants is chosen by the chemical, its concentration and its temperature, because no grade resists every acid. 316L suits moderate sulphuric and phosphoric acid, 904L was developed for sulphuric acid, and the four grades tested rate 2 in every hydrochloric acid condition from 5 percent, except 904L at 5 percent and 20 °C. Published laboratory ratings, with their conditions, are the first guide.
5 percent sulphuric acid at 60 °C by grade
Rating for each grade, annealed material
- 304L: 2
- 316L: 1
- 317L: 0
- 904L: 0
- 0
- Corrosion rate below 0.1 mm/year
- 1
- 0.1 to 1.0 mm/year
- 2
- Above 1.0 mm/year
Chloride matters in a chemical plant as much as acid does. 304L is sensitive to pitting and crevice corrosion even in relatively low chloride solutions, and grades for seawater and chloride service rank the alternatives by PREN.
How Are Corrosion Tables Read?
A corrosion table gives a rate rating for each grade at a stated concentration and temperature, and the rating is not a service guarantee.
The ratings here come from one producer's laboratory tables for tube grades: 304L, 316L, 317L and 904L. 317L here is the 18Cr13Ni3Mo grade. The legend is:
| Rating | Meaning |
|---|---|
| 0 | corrosion rate below 0.1 mm/year |
| 1 | 0.1 to 1.0 mm/year |
| 2 | above 1.0 mm/year |
| p | risk of pitting and crevice corrosion |
| s | risk of stress corrosion cracking |
Concentrations are weight percent. The tests use pure chemicals in water nearly saturated with air, annealed material and clean surfaces. Rates can differ in oxygen-free solutions. The tables are not strictly comparable with actual service conditions.
How Does Stainless Steel Behave in Sulphuric Acid?
904L rates the same as or better than the other three grades in most sulphuric acid conditions, and 304L rates worst once the acid is warm.
| Acid and temperature | 304L | 316L | 317L | 904L |
|---|---|---|---|---|
| 3 percent at 20 °C | 0 | 0 | 0 | 0 |
| 1 percent at 70 °C | 1 | 0 | 0 | 0 |
| 0.5 percent boiling | 2 | 1 | 1 | 1 |
| 1 percent boiling (100 °C) | 2 | 1 | 1 | 1 |
| 5 percent at 60 °C | 2 | 1 | 0 | 0 |
| 10 percent at 80 °C | 2 | 2 | 2 | 1 |
| 20 percent at 40 °C | 2 | 1 | 1 | 0 |
| 98 percent at 30 °C | 0 | 0 | 0 | 0 |
| 98 percent at 40 °C | 0 | 0 | 0 | 1 |
| 98 percent at 80 °C | 2 | 2 | 2 | 2 |
The steel in 904L sheets and plates was originally developed for use in sulphuric acid. Jindal states 904L handles sulphuric acid at 0 to 100 percent up to about 35 °C, which agrees with the table at 3 percent and at 98 percent and 30 °C. 316L is used in inorganic acids such as phosphoric and sulphuric at moderate concentrations and temperatures, and in sulphuric acid above 90 percent at low temperature.
How Does Stainless Steel Behave in Phosphoric Acid?
All four grades rate 0 in pure phosphoric acid in the conditions listed first, up to 30 percent, and 304L separates at 100 °C from 30 percent.
All four grades rate 0 at these conditions:
| Acid | Temperatures where all four rate 0 |
|---|---|
| 1 percent | 20 °C, 100 °C, 140 °C |
| 3 percent | boiling |
| 5 percent | 20 to 60 °C, 85 °C, boiling |
| 10 percent | 40, 60, 80 °C, boiling (101 °C) |
| 20 percent | 35 °C, 60 °C, boiling (102 °C) |
| 30 percent | 20 to 35 °C, 60 °C |
The next table lists the conditions where the grades differ.
| Acid and temperature | 304L | 316L | 317L | 904L |
|---|---|---|---|---|
| 30 percent at 100 °C | 1 | 0 | 0 | 0 |
| 40 percent at 100 °C | 1 | 0 | 0 | 0 |
| 40 percent boiling (106 °C) | 2 | 1 | 1 | 1 |
| 50 percent at 100 °C | 1 | 1 | 1 | 0 |
| 50 percent boiling (110 °C) | 2 | 2 | 1 | 1 |
| 60 percent at 100 °C | 2 | 1 | 1 | 0 |
| 60 percent boiling (116 °C) | 2 | 2 | 2 | 1 |
The values are for pure acid. Process acid with impurities is not covered by these ratings. A producer reports that 904L has been used with success in many applications in phosphoric acid plants.
How Does Stainless Steel Handle Hydrochloric Acid?
Stainless steel handles hydrochloric acid only when it is dilute and cool: 304L rates 2 even at 1 percent and 50 °C, and only 317L and 904L reach rating 0, with a pitting risk.
Jindal states 904L is suitable only at 1 to 2 percent hydrochloric acid. The ratings here carry the letter p for pitting and s for stress corrosion cracking.
| Acid and temperature | 304L | 316L | 317L | 904L |
|---|---|---|---|---|
| 1 percent at 50 °C | 2 | 1p | 0p | 0p |
| 1 percent at 60 °C | 2 | 2 | 1p | 1p |
| 1 percent at 80 °C | 2 | 2 | 1ps | 1ps |
| 1 percent boiling | 2 | 2 | 2 | 2 |
| 2 percent at 20 °C | 2 | 1p | 1p | 0p |
| 2 percent at 60 °C | 2 | 2 | 2 | 1p |
| 3 percent at 20 °C | 2 | 1p | 1p | 0p |
| 3 percent at 60 °C | 2 | 2 | 2 | 1p |
| 3 percent at 70 °C | 2 | 2 | 2 | 1p |
| 3 percent at 80 °C | 2 | 2 | 2 | 2 |
From 5 percent to 37 percent, 304L, 316L and 317L rate 2 in all 11 tested conditions. 904L rates 1 at 5 percent and 20 °C and 2 in all other conditions. A producer states that 904L suits process solutions with small amounts of hydrochloric acid, and that the risk of pitting should be kept in mind.
Which Grades Resist Caustic Soda?
304L, 316L, 317L and 904L all rate 0 in caustic soda (sodium hydroxide) in the cool and warm conditions listed first, up to 40 percent. Hot and boiling solutions rate 1 or 2, with a stress corrosion risk at boiling.
All four grades rate 0 at these conditions:
| Caustic | Temperatures where all four rate 0 |
|---|---|
| 10 percent | 20 °C, 90 °C, boiling (103 °C) |
| 20 percent | 20 °C, 90 °C |
| 25 percent | 20 °C, boiling (112 °C) |
| 30 percent | 20 °C, 100 °C |
| 40 percent | 80 °C, 90 °C |
At 30 percent boiling (116 °C), 304L rates 1s and the other three rate 0s. The next table lists the hotter conditions.
| Caustic and temperature | 304L | 316L | 904L |
|---|---|---|---|
| 40 percent at 100 °C | 1 | 1 | 0 |
| 40 percent boiling (128 °C) | 1s | 1s | 1s |
| 50 percent at 60 °C | 0 | 0 | 0 |
| 50 percent at 90 °C | 1 | 1 | 0 |
| 50 percent boiling (140 °C) | 1s | 1s | 1s |
| 60 percent boiling (160 °C) | 2 | 2 | 2 |
| 70 percent boiling (180 °C) | 2 | 2 | 2 |
317L rates 1 at 40 percent and 100 °C and at 50 percent and 90 °C, like 316L.
How Does Stainless Steel Behave in Nitric Acid?
904L is less resistant to nitric acid than 304L, because of its molybdenum.
The Huey test is the nitric acid test for intergranular attack: boiling 65 percent nitric acid, five periods of 48 hours. The product limit for 304L is 0.40 mm/year annealed and 0.60 mm/year sensitised. That is a product test limit, not a service limit. Sensitisation is the formation of chromium carbides at grain boundaries, in about 450 to 850 °C, which weakens corrosion resistance.
Stabilised grades have titanium (321) or niobium added to tie up carbon. With some limitations, 321 has the same resistance in nitric acid as 304, which is not stabilised, and titanium stabilisation improves resistance to intergranular corrosion. No nitric acid ratings are printed here.
How Do Stainless Steels Behave in Organic Acids?
316L has good resistance to organic acids at high concentrations and moderate temperatures. 304L has good resistance at moderate temperatures.
How Do 304L and 316L Differ in Plants?
316L holds 2.00 to 3.00 percent molybdenum, and it resists attack better than 304.
The L means low carbon, 0.030 percent maximum, which reduces carbide formation during welding. 316L has better resistance to intergranular corrosion than 316, shown by the Strauss test: 24 hours in boiling 12 percent sulphuric acid with 6 percent copper sulphate. Low-carbon 304L and 316L are compared on their own page.
304 and 316 can crack under tensile stress in chloride above about 50 °C.
317L has a PREN of 27.9 calculated from minimum composition, and a producer figure of greater than 28. PREN is the pitting resistance equivalent number. 316 uses include chemical processing equipment, and duplex 2205 is used in chemical processing and chemical tanks. The base metals are 316L sheets and plates, 317L sheets and plates and duplex 2205 sheets and plates.
Why Test the Actual Duty?
Laboratory tables are guides, because small changes in the environment change the result in service.
ASTM G31 is a guide to laboratory immersion tests, mainly for mass loss. G31 does not cover localised attack or environmentally assisted cracking. ASTM A262 practices detect intergranular attack only and do not predict resistance to other forms such as pitting or stress corrosion cracking. Impurities, aeration and fluid velocity are not in the tables. The types of stainless steel corrosion show why each needs its own test.
How Does Cost Compare Between Chemical-Duty Grades?
The price of each grade follows its nickel and molybdenum content, and stainless steel price factors lists the other factors.
The stainless steel grade selector narrows the grade by service, and each grade page carries its own rates.
We supply 316L, 317L, 904L and duplex 2205 sheets and plates from Mumbai, and a mill test certificate comes with every supply. We can check a duty against these ratings if you send the chemical, concentration and temperature.
Frequently Asked Questions
Which Stainless Steel Is Best for Sulphuric Acid?
904L rates the same as or better than the other three grades in most producer table conditions, and it was developed for sulphuric acid. At 5 percent and 60 °C it rates 0, against 1 for 316L and 2 for 304L. At 98 percent and 40 °C the order reverses: 304L, 316L and 317L rate 0 and 904L rates 1.
Can 316L Handle Hydrochloric Acid?
No, only in dilute, cool acid. In the producer table 316L rates 1p at 1 percent and 50 °C and 2 at 1 percent and 60 °C. At 5 percent and above it rates 2 in every tested condition.
What Is the Nitric Acid Limit for 304L?
304L is tested in boiling 65 percent nitric acid, five periods of 48 hours (Huey test), with a product limit of 0.40 mm/year annealed. That is a test limit, not a service limit, and no nitric acid ratings are printed here. 904L is less resistant to nitric acid because of its molybdenum.
Is Stainless Steel Suitable for Caustic Soda?
Yes, at the conditions rated 0, such as 10 percent at 20 °C and 40 percent at 80 °C. At 60 percent and 70 percent boiling all rate 2, and at boiling stress corrosion cracking is a risk.
Why Is 904L Used in Phosphoric Acid Plants?
904L rates 0 in pure phosphoric acid to 30 percent and rates better than 316L at 50 and 60 percent at 100 °C. A producer reports successful use in many phosphoric acid plants.
Can a Corrosion Table Replace a Plant Trial?
No, a corrosion table cannot replace a trial. The producer states the tables are not strictly comparable with actual service, and performance can change with minor changes in the environment.
What Do the Ratings 0, 1 and 2 Mean?
0 is a corrosion rate below 0.1 mm/year, 1 is 0.1 to 1.0 mm/year and 2 is above 1.0 mm/year. The letters p and s add a risk of pitting or stress corrosion cracking.